Filtration Control Fluid Loss Additive

Filtration Control Fluid Loss Additive

Applicable for medium and high temperature wells.
Control fluid loss in lightweight,normal density or high density cement slurries.
Applicable mixing water: from fresh water to salt-saturated water.
Used below temperature of 204.4℃ (400℉, BHCT).
Send Inquiry
Description

Tianjin Kelioil Engineering Material and Technology Co., Ltd. is one of the leading manufacturers and suppliers of filtration control fluid loss additive in China. Please feel free to buy high quality filtration control fluid loss additive at low price from our factory. If you have any enquiry about free sample, please feel free to email us.

 

1. Description

CG610, a high-performance additive engineered by Kelioil, is specifically crafted to boost the performance of cement slurries in oil and gas well cementing operations. Its formulation is designed to refine crucial properties, including fluid loss control, stability, and compatibility with diverse cement types and environmental conditions. Available in both powder and liquid formulations, the product offers enhanced flexibility for application across a range of construction scenarios.

Liquid Medium Temperature Retarder Cementing
Kelioil Warehouse Fluid Loss Additive
High Temperature HT Retarder Oil Cementing
Fluid Loss Additive Ready to Tianjin Port

2. Application

CG610 finds primary application in oilfield cementing engineering, with suitability for medium to high-temperature well environments ranging from 30°C to 180°C (86°F to 356°F). It demonstrates compatibility with a variety of cement types, including Class G, Dyckerhoff, API Class B, and API Class H, while also being applicable across diverse water systems such as freshwater, saltwater, seawater, and saturated brine. Its core functionalities encompass minimizing fluid loss, enhancing slurry stability, and preserving optimal rheological characteristics, all of which contribute to improved wellbore sealing integrity.

Offshore cementing project.png

 

3. Common Name

Fluid loss control additive for cement slurries; Performance enhancer for oilfield cementing.

 

4. Advantage

Unrivaled Fluid Loss Management: Significantly restricts API fluid loss to less than 50 mL (at 500 psi for 30 minutes), surpassing API specifications.

Broad Thermal Adaptability: Maintains consistent performance across a temperature range of 30°C to 180°C, making it ideal for medium and high-temperature well environments.

Exceptional Compatibility: Seamlessly integrates with common additives such as retarders, dispersants, gas migration inhibitors, and salt - resistant agents.

Rheology - Friendly Design: Its optimized composition ensures no increase in slurry viscosity, enabling trouble - free pumping operations.

Robust Stability: Effectively prevents slurry segregation and sedimentation, thereby enhancing wellbore sealing efficiency.

Multi - functional Application: Compatible with diverse cement types and water systems, including saltwater, showcasing excellent salt tolerance.

User - Oriented Formulation: Offered in both powder and liquid forms, it supports dry or wet mixing methods, streamlining on - site implementation.

Oil Well Cement Additives
KELIOIL Workshop Fluid Loss Additive
Oil Well Cementing Additives
KELIOIL Warehouse Fluid Loss Additive

5. Package

Powder variant: Available in 25 kg bags or 500 kg bulk bags (custom packaging options are provided upon request).

Liquid variant: Supplied in 200 L drums or 1000 L IBC containers (OEM services and custom packaging solutions are supported).

 

6.Safety and Handling Guidelines

Storage: Store the product in a cool, dry environment with adequate ventilation, keeping it away from direct sunlight and ignition sources. Ensure containers are tightly sealed when not in use to maintain product integrity.

Handling: Always wear suitable personal protective equipment (PPE), including gloves, safety goggles, and dust masks, during handling. This safeguards against direct skin or eye contact and prevents inhalation of dust particles.

First Aid Procedures: In the event of skin contact, rinse the affected area thoroughly with water. For eye contact, immediately flush the eyes with plenty of water; if irritation persists, seek prompt medical attention. If accidentally ingested, do not attempt to induce vomiting and consult a healthcare professional without delay.

Disposal: Dispose of any unused product and packaging materials in strict compliance with local environmental regulations. Under no circumstances should the product be discharged into water bodies or soil.

 

For comprehensive safety details, please refer to the Material Safety Data Sheet (MSDS) accompanying the product.

 

Product video

 

 

Company profile

factoryteam and office

 

Founded in 2006, Tianjin Kelioil specializes in cementing additives, including fluid loss additives and retarders. Boasting a 30,000-square-meter production base and an annual production capacity of 10,000 metric tons, the company adheres to ISO9001 and API 10A standards. Committed to eco-friendly practices, it operates automated production lines and conducts collaborative R&D with Japanese universities. Its products are exported to regions such as the Middle East and Indonesia. The company provides free samples, maintains stock for prompt delivery, offers 20GP customized orders within 7 days, and supports OEM packaging services.

Certificate

 

oilfield cementing additives certificate

 

 

 

KELIOIL's fluid loss additives, backed by advanced formulations and technologies, fully meet the stringent requirements for stability and reliability in fluid loss control performance. In practical applications, these additives can stably reduce API fluid loss to below 30 mL (under the conditions of 500 psi pressure and 30 minutes), far exceeding the upper limit of 50 mL specified in API standards. Even under harsh working conditions such as high temperatures (180°C), high pressures, and high salinity environments, they maintain excellent and consistent fluid loss control capabilities.

 

KELIOIL's fluid loss additives also feature exceptional anti-interference performance. When compounded with various types of cement (such as Class G and API Class H) and common admixtures (including retarders and dispersants), they do not experience performance degradation, ensuring the overall stability of the cement slurry system. Moreover, they can quickly adapt to diverse water quality conditions, ranging from freshwater and seawater to saturated brine, maintaining stable and reliable fluid loss control effects. This consistent performance effectively prevents issues like excessive filtration cake formation or rapid thickening of the cement slurry caused by fluid loss, thus laying a solid foundation for high-quality well cementing operations.

 

 

Hot Tags: filtration control fluid loss additive, China filtration control fluid loss additive manufacturers, suppliers, factory, cementing accelerator, efficient cementing additive, enhanced cementing additive, environmentally friendly cementing additive, oil well cementing additive, proven cementing additive

Send Inquiry