NZCQ2220R Dual Cell HTHP Consistometer (Flagship Ultimate Version)

NZCQ2220R Dual Cell HTHP Consistometer (Flagship Ultimate Version)

●Maximum Temperature: 315℃(600℉)
●Maximum Pressure: 275MPa(40000psi)
●Rotation Speed:0-300 rpm
●Viscosity Range:0-100Bc
●Input Voltage: 100-110V,60Hz/220V,50Hz
●API 10 Specification
●Pressure Of Cooling Water: 0.2-0.5 MPa
●Connector Size Of Cooling Water Pipe: Innter Diameter: 10 mm
●Air Supply Pressure: 0.4-0.7 MPa
●Weight: 950kg
●Dimension(W*D*H): 127*80*177cm
Send Inquiry
Description

Tianjin Kelioil Engineering Material and Technology Co., Ltd. is one of the leading manufacturers and suppliers of nzcq2220r dual cell hthp consistometer (flagship ultimate version) in China. Please feel free to buy high quality nzcq2220r dual cell hthp consistometer (flagship ultimate version) at low price from our factory. If you have any enquiry about free sample, please feel free to email us.

 

NZCQ2220R Dual Cell HTHP Consistometer (Flagship Ultimate Version)

 


NZCQ2220R Dual Cell HTHP Consistometer is a flagship HPHT Consistometer designed for high-efficiency cement slurry thickening time evaluation under simulated downhole temperature and pressure conditions.

Also known as a Dual Cell Pressurized Consistometer or Dual Cell Cement Thickening Time Tester, this model features two independent test cells for simultaneous testing, making it ideal for high-throughput oilwell cement laboratories and R&D centers.

Model: NZCQ2220R
Type: Dual Cell HPHT Consistometer
Series: Deep Ocean Series (Ultimate Version)
Application: Cement slurry thickening behavior and pumpability evaluation
Testing Standard: API Spec 10A ; GB/T 10238

 

NZCQ2220R Dual Cell HTHP Consistometer (Flagship Ultimate Version)

 

1. What Is the NZCQ2220R Dual Cell HTHP Consistometer Used For?


The NZCQ2220R Dual Cell HPHT Consistometer is engineered to perform **two independent cement slurry thickening time tests at the same time**. It simulates real downhole high temperature and high pressure conditions to evaluate cement slurry performance, consistency evolution (Bc vs time), and additive effects with higher lab efficiency.

This instrument is widely applied in:
- High-volume cementing laboratory thickening time testing
- Cement slurry system design and optimization
- Cement additive screening and comparison
- Quality assurance for cementing service companies
- Cementing R&D centers requiring high throughput testing

 

 

 

 

2. Why Choose NZCQ2220R Dual Cell HPHT Consistometer?


Dual Independent Test Cells
Two completely independent test chambers allow **parallel testing of two cement slurry samples**. This doubles lab throughput compared with single cell instruments and is ideal for busy testing schedules.

Large Touch Screen with Dual Curve Display
The high-resolution touch screen can display two sets of thickening time curves (Bc vs time) side by side, supporting quick comparison of cement slurry behaviors.

Advanced Temperature & Pressure Control with EUROTHERM
Each cell supports programmable temperature and pressure schedules controlled via EUROTHERM and PLC, ensuring accurate simulation of downhole environments and minimizing operator intervention.

Stainless Steel Durable Structure
The instrument casing and internal high-pressure components are made of premium stainless steel, enhancing corrosion resistance and extending service life under frequent high temperature and pressure cycles.

Enhanced Oil Level Monitoring System
Real-time oil level tracking for both test cells ensures safer operation and reduces the risk of operational interruptions due to oil shortage or overflow.

Built-In Cast-Aluminum Chiller + External Chiller Interface
The optimized cast-aluminum chiller accelerates cool-down time. An external chiller connection is available for sub-ambient temperature testing, expanding the instrument's testing range.

One-Button Automatic Operation
Once parameters are set, the system runs automatically, reducing manual intervention and improving repeatability of results.

Alarm & Safety System
Oil level alarms, pressure overshoot alarms, and temperature alarms are displayed directly on the touch screen, enabling faster troubleshooting and safer lab environments.

 

 

 

 

3. Technical Specifications of NZCQ2220R Dual Cell HTHP Consistometer

 

 

 

Item Specification
Model NZCQ2220R
Type Dual Cell HPHT Consistometer
Maximum Temperature 315 degrees Celsius
Maximum Pressure 275 MPa
Consistency Measurement Range 0-100 Bc
Consistency Unit Bearden Units (Bc)
Temperature Controller EUROTHERM (touch screen parameter setting)
Control System PLC
Cooling System Built-in cast-aluminum + external chiller support
Stirring Speed 0-300 rpm
Data Output Dual curve display, screenshots export
Power Supply AC 100-110V 60Hz;220V 50Hz
Heater Power 4000w*2
Input Power 4500w*2
Dimensions 127*80*177 cm
Weight 950 kg

 

 

 

4. API & International Standards Supported


The NZCQ2220R Dual Cell HPHT Consistometer is engineered to help labs generate thickening time data compatible with industry standards, including:
- API Spec 10A
- GB/T 10238

It supports programmable BHCT/BHST schedules to simulate typical downhole conditions.

 

 

 

 

5. Dual Cell Testing: Efficiency & Comparison


A key advantage of the dual cell design is the ability to test two slurries simultaneously, meaning you can:
✅ Compare cement slurry designs side by side
✅ Evaluate two additive systems at once
✅ Reduce lab turnaround time by up to 50%

This makes the NZCQ2220R perfect for:

Service companies with heavy testing volume

Cement R&D teams conducting additive screening

QC departments handling daily cement batch testing

 

 

 

 

6. Typical Applications for Cement Systems


This dual cell cement testing instrument covers a wide range of oilwell cement slurry systems:
- Class G / Class H slurries
- Salt-resistant high temperature slurries
- Lightweight / foamed cement slurries

 

 

 

 

7. Real-Time Dual Curve Output & Data Management


The LCD touch screen displays both test curves simultaneously (Cell A & Cell B), helping you quickly assess differences in slurry behavior. Screenshots may be saved/exported for reports and traceability.

 

 

 

 

8. Delivery, Installation & After-Sales Support


We provide comprehensive support for the NZCQ2220R Dual Cell HPHT Consistometer:
- Operation manual and wiring guidance
- On-site/online commissioning support
- Laboratory operator training
- Spare parts and maintenance services
- Warranty: 【12 Mouths】

Delivery lead time: 【45 days】
Packing: export-standard wooden case

 

 

 

 

9. Frequently Asked Questions (FAQ)


Q1: What are the key differences between dual cell and single cell?
A: Dual cell allows two independent tests simultaneously, increasing efficiency and enabling direct comparison of cement systems.


Q2: Can each test cell use separate temperature/pressure schedules?
A: Yes, each cell can run independent profiles to support comparative testing.

Q3: Does this instrument support screenshots export?
A: Yes - dual curve screenshots can be exported from the touch screen for lab documentation.

Q4: What accessories should be ordered?
A: Recommended spares include dual slurry cup seal kits, dual gasket kits, sensors, etc.

 

 

 

 

10. Request a Quotation for NZCQ2220R Dual Cell HTHP Consistometer


Contact us for quotation, datasheets, and technical details for your lab's dual cell HPHT testing needs.


Company: Tianjin Nithons Technology Co., Ltd.

 

 

Hot Tags: nzcq2220r dual cell hthp consistometer (flagship ultimate version), China nzcq2220r dual cell hthp consistometer (flagship ultimate version) manufacturers, suppliers, factory

Send Inquiry