Mid Temperature Retarder*Applicable for low-to-moderate temperature system, used below 90℃ (194℉, BHCT).read more
*Applicable mixing water: from fresh water to half-saturated salt water.
*Mixed with water when... -
Salt Resistant Fluid Loss Additive*Control fluid loss in normal density cement slurries, lightweight or high density cement slurries.read more
*Used below temperature of 204.4℃(400℉, BHCT).
*Applicable mixing water: from fresh... -
Well Cementing Retarder*Cost-effective.read more
*Easy to mix.
*Stable performance up to 400°F.
*Applicable to low, normal and high-density cement slurries.
*Compatible with fresh water to... -
Fluid-Loss-Control Additive FLACCG613 series products, polymer - type additives, control cement slurry fluid loss during cementing.read more
Prevent thickening time and strength reversal with temperature.
Suitable for normal... -
Polymer AMPS Fluid Loss Additive For Oil CementingCG613 series products, polymer - type additives, control cement slurry fluid loss during cementing.read more
Prevent thickening time and strength reversal with temperature.
Suitable for normal... -
Low Temperature Coagulation Promoting Type Fluid Loss Add...Reducing fluid loss and accelerating coagulation.read more
White or faint yellow powder
Suitable for normal density, low density and high density cement slurry systems.
Used below... -
High Temperature HT Retarder Oil Cementing●Accurately targets working temperature below 400℉(204.4℃,BHCT).read more
●Thickening time has a linear relation with the added amount. The Right-Angle thickening curve can be achieved, and mutation... -
Anti Reversal Fluid Loss AdditivesCG613 series products, polymer - type additives, control cement slurry fluid loss during cementing.read more
Prevent thickening time and strength reversal with temperature.
Suitable for normal... -
Oil Well Cementing Fluid Loss ReducerIdeal for oil well cementing in low - to - moderate temperature conditions, offering excellent cost - efficiency.read more
Primarily functions to regulate fluid loss in cement slurries of normal... -
CH210L Medium Temperature Retarder For Oil CementingThe CH210L medium temperature retarder precisely targets cementing operation environments below 194 degrees Fahrenheit. ✔ The thickening time can be freely adjusted, with excellent dosage...read more
-
Oil Well Retarder*Thickening time has a linear relation with the added amount. The Right-Angle thickening curve can be achieved, and mutation of slurry consistency is small.read more
*Strength of set cement develops... -
Oil Field Cement Defoamer*High efficient foam preventer which can quickly eliminate the foam generated in the cement slurry. Good inhibitive and degassing effect.read more
*Disperses well in the cement slurry, and inhibits...
Diacel® HTR-100 Cement Retarder Additive is a mid-range temperature cement retarder, effective between 175 to 275 °F. The powder form is typically dry blended with the cement...
Impact’s LTR, XTR and HTR® cement retarders provide more linear and repeatable thickening time control compared with generic retarders. Learn more now....
Retarder control unit temperature. Retarder control unit temperature is too high. Possible heating from an external heat source. MID222 PPID210 FMI3. Moderator valve. ... MID 222PSID1 FMI3. Power...
This advancement introduces an industry-dependable mid-temperature retarder (MTR) formula that spans the entire mid-temperature range, enabling the design of both shorter and longer...
MTR® is an effective mid-temperature cement retarder. MTR is engineered for effectiveness across the entire mid temperature range, including the difficult to retard 200-230° F (93-110° C)...
Apr 3, 2017 · Abstract. This paper presents a new high temperature retarder that can effectively delay the setting time of an oil and gas cement up to 450 °F via a single polymer only instead...